JustView FAQs


Error message: error 2002 fatal error csg_ts_m2n_mean
The sheet will be opened even if the user has closed the window.



Question:
Error message: error 2002 fatal error csg_ts_m2n_mean
The sheet will be opened even if the user has closed the window.

Answer:
In order for JustView to display a MEDUSA sheet correctly, JustView requires according information from the Template MEDUSA sheet. This sheet must also be adjusted if there are Code/DDL modifications because not DDL conform elements may be contained. The Template was generated with standard MEDUSA.

The sheet is located at: /cfg/csg_template.she
----------------------------------------------------------------
If the template sheet can not be opened with the customizations, open the flat-file in BaCIS1, using:

errpau off
errmes off
macro csg_template.flt

----------------------------------------------------------------
After the sheet has been modified with the customer Code/DDL, error messages will no longer occur.


Back to top

Support >> FAQ >> 5/250